{"product_id":"xkc-y26-v-dc-5-24v-non-contact-liquid-level-sensor","title":"XKC-Y26-V-DC 5-24V Non-Contact Liquid Level Sensor","description":"\u003cdiv class=\"product_info\"\u003e\n\u003ch2 class=\"sing--sub-heading\"\u003e\u003cspan style=\"font-size: 18.72px;\"\u003eXKC-Y26S-V-DC 5-24V Non-Contact Liquid Level Sensor\u003c\/span\u003e\u003c\/h2\u003e\nThe \u003cstrong\u003eXKC-Y26S-V-DC 5-24V\u003c\/strong\u003e is a \u003cstrong\u003enon-contact capacitive liquid level sensor\u003c\/strong\u003e designed for accurate liquid detection through the outer wall of \u003cstrong\u003enon-metallic containers and pipes\u003c\/strong\u003e. It detects the presence of liquid without direct contact with the medium, making it suitable for sealed containers, corrosive liquids, water tanks, pipelines, and automation systems. \u003cbr\u003e\u003cbr\u003eThis model operates from \u003cstrong\u003eDC 5V to 24V\u003c\/strong\u003e and provides a \u003cstrong\u003ehigh and low level voltage output interface\u003c\/strong\u003e. It offers \u003cstrong\u003ehigh sensitivity, stable performance, adjustable sensing sensitivity, strong anti-interference capability, and IP67 protection\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eNon-contact liquid level detection through non-metallic walls\u003c\/li\u003e\n\u003cli\u003eNo direct contact with liquid\u003c\/li\u003e\n\u003cli\u003eDC 5V to 24V wide operating voltage range\u003c\/li\u003e\n\u003cli\u003eHigh and low level voltage output\u003c\/li\u003e\n\u003cli\u003eSuitable for plastic, glass, ceramic, acrylic, PC, PVC and PPR materials\u003c\/li\u003e\n\u003cli\u003eSuitable for cold, hot and boiling liquid detection\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity and stable sensing performance\u003c\/li\u003e\n\u003cli\u003eStrong anti-interference capability\u003c\/li\u003e\n\u003cli\u003eAdjustable sensitivity\u003c\/li\u003e\n\u003cli\u003eBuilt-in reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eBuilt-in output overcurrent protection\u003c\/li\u003e\n\u003cli\u003eIP67 waterproof protection\u003c\/li\u003e\n\u003cli\u003eNo drilling of the container is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWorking Principle\u003c\/h3\u003e\nThe sensor works using the \u003cstrong\u003ecapacitive sensing principle\u003c\/strong\u003e. When no liquid is present near the sensing surface, the sensor maintains its normal static capacitance. As the liquid level approaches the sensing point, the liquid introduces additional parasitic capacitance. \u003cbr\u003e\u003cbr\u003eThe internal control circuit detects this capacitance change and converts it into an electrical signal. When the measured change exceeds the set threshold, the sensor determines that liquid has reached the sensing position and changes its output state.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eItem Type: Non-Contact Liquid Level Sensor\u003c\/li\u003e\n\u003cli\u003eModel Name: XKC-Y26S-V-DC 5-24V\u003c\/li\u003e\n\u003cli\u003eOperating Principle: Capacitive sensing\u003c\/li\u003e\n\u003cli\u003eInput Voltage: DC 5V to 24V\u003c\/li\u003e\n\u003cli\u003eOutput Mode: High and low level voltage output\u003c\/li\u003e\n\u003cli\u003eHigh Level Output Voltage: Vin\u003c\/li\u003e\n\u003cli\u003eLow Level Output Voltage: 0V\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: ≤ 5mA\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current: ≤ 100mA\u003c\/li\u003e\n\u003cli\u003eResponse Time: 500mS\u003c\/li\u003e\n\u003cli\u003eLevel Accuracy: ±1.5mm\u003c\/li\u003e\n\u003cli\u003eApplicable Pipe Diameter: ≥ 10mm\u003c\/li\u003e\n\u003cli\u003eWaterproof Rating: IP67\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC + ABS V0 fire-retardant material\u003c\/li\u003e\n\u003cli\u003eOvercurrent Protection Threshold: 150mA\u003c\/li\u003e\n\u003cli\u003eSafety Certification: CE\u003c\/li\u003e\n\u003cli\u003eEnvironmental Certification: ROHS-2.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eMechanical Drawing \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/Mechanical_drawing.png?v=1788331579\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eGap Requirement Between Sensor and Container Wall\u003c\/h3\u003e\nThe sensing surface should be attached \u003cstrong\u003etightly to the outer wall of the container\u003c\/strong\u003e. Use AB glue or another durable adhesive for secure installation. The gap between the sensor contact surface and the container wall should be \u003cstrong\u003eless than 0.5mm\u003c\/strong\u003e. For optimum sensing accuracy, \u003cstrong\u003eno gap is recommended\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eGap Requirement Between Sensor and Container Wall drawing\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/gap.png?v=1788331680\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFlat Container Installation\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/installation_diagram.png?v=1788331895\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePipe Installation\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/ChatGPT_Image_Sep_2_2026_11_47_18_AM_4.png?v=1788331826\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\" style=\"text-align: left;\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eSensitivity Adjustment\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eUse a small screwdriver to adjust the sensitivity\u003c\/li\u003e\n\u003cli\u003eRotate counterclockwise to increase sensitivity\u003c\/li\u003e\n\u003cli\u003eRotate clockwise to decrease sensitivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/Sensitibity_adjustment.png?v=1788331263\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWall Thickness \u0026amp; Pipe Diameter Selection\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/table.png?v=1788331326\" alt=\"\"\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWiring Diagram\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/diagram1.png?v=1788331509\" alt=\"\"\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eOperating Temperature Range: -20°C to 105°C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eLevel Accuracy: ±1.5mm\u003c\/li\u003e\n\u003cli\u003eMinimum Applicable Pipe Diameter: 10mm\u003c\/li\u003e\n\u003cli\u003eMaximum Wall Thickness: Up to 20 ± 2mm depending on pipe diameter\u003c\/li\u003e\n\u003cli\u003eMaterial: PC + ABS V0 fire-retardant material\u003c\/li\u003e\n\u003cli\u003eWaterproof Performance: IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eWater tanks and reservoirs\u003c\/li\u003e\n\u003cli\u003eLiquid storage containers\u003c\/li\u003e\n\u003cli\u003eWater dispensers\u003c\/li\u003e\n\u003cli\u003eIndustrial liquid level monitoring\u003c\/li\u003e\n\u003cli\u003eChemical containers\u003c\/li\u003e\n\u003cli\u003eNon-metallic pipelines\u003c\/li\u003e\n\u003cli\u003eAutomatic filling systems\u003c\/li\u003e\n\u003cli\u003eLiquid level alarms\u003c\/li\u003e\n\u003cli\u003eHome appliances\u003c\/li\u003e\n\u003cli\u003eAutomation and IoT projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePackage Includes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds ls-n\"\u003e\n\u003cli\u003e1 × XKC-Y26S-V-DC 5-24V Non-Contact Liquid Level Sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KitsGuru","offers":[{"title":"Default Title","offer_id":48612253892860,"sku":"KG1316","price":524.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/5-24VNon-ContactLiquidLevelSensor_1.jpg?v=1767700296","url":"https:\/\/kitsguru.com\/es\/products\/xkc-y26-v-dc-5-24v-non-contact-liquid-level-sensor","provider":"KitsGuru","version":"1.0","type":"link"}