{"product_id":"mics-5524-co-h2-ch4-gas-sensor-detection-module","title":"MICS-5524 CO H2 CH4 Gas Sensor Detection Module","description":"\u003cdiv class=\"product_info\"\u003e\n\u003ch2 class=\"sing--sub-heading\"\u003e\u003cspan style=\"font-size: 18.72px;\"\u003eMiCS-5524 Carbon Monoxide, Hydrogen \u0026amp; Methane Gas Sensor Module\u003c\/span\u003e\u003c\/h2\u003e\nThe \u003cstrong\u003eMiCS-5524 Gas Sensor Module\u003c\/strong\u003e is a robust \u003cstrong\u003eMEMS-based gas detection sensor\u003c\/strong\u003e designed for detecting \u003cstrong\u003ecarbon monoxide (CO)\u003c\/strong\u003e and various combustible gases. It is suitable for \u003cstrong\u003eindoor air quality monitoring, natural gas leakage detection, breath analysis, and early fire detection\u003c\/strong\u003e. \u003cbr\u003e\u003cbr\u003eThis sensor is sensitive to multiple gases including \u003cstrong\u003eCO, ammonia, ethanol, hydrogen, methane, propane, and iso-butane\u003c\/strong\u003e. However, it cannot distinguish between individual gases and provides a combined response based on detected gas concentration. The analog output voltage increases proportionally with gas concentration. \u003cbr\u003e\u003cbr\u003eThe MiCS-5524 breakout board is intended for \u003cstrong\u003eeducational, hobby, and experimental use only\u003c\/strong\u003e and is not suitable for safety-critical or medical applications. Calibration is required for precise gas measurement.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eMEMS-based multi-gas detection sensor\u003c\/li\u003e\n\u003cli\u003eSensitive to carbon monoxide and combustible gases\u003c\/li\u003e\n\u003cli\u003eAnalog voltage output proportional to gas concentration\u003c\/li\u003e\n\u003cli\u003eSupports heater enable (EN) pin for power saving\u003c\/li\u003e\n\u003cli\u003eLow power heater consumption (25–35 mA typical)\u003c\/li\u003e\n\u003cli\u003eCompact size with lightweight design\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor air quality and gas leakage monitoring\u003c\/li\u003e\n\u003cli\u003eAssembled and tested breakout board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eDetectable Gases \u0026amp; Ranges\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eCarbon Monoxide (CO): ~1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eAmmonia (NH₃): ~1 to 500 ppm\u003c\/li\u003e\n\u003cli\u003eEthanol: ~10 to 500 ppm\u003c\/li\u003e\n\u003cli\u003eHydrogen (H₂): ~1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eMethane \/ Propane \/ Iso-Butane: ~1000+ ppm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eItem Type: Gas Sensor\u003c\/li\u003e\n\u003cli\u003eModel Name: MiCS-5524\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 4.9 – 5.1 V DC\u003c\/li\u003e\n\u003cli\u003eHeater Power Dissipation: 88 mW\u003c\/li\u003e\n\u003cli\u003eHeater Current: 25 – 35 mA (typical)\u003c\/li\u003e\n\u003cli\u003eOutput Type: Analog voltage\u003c\/li\u003e\n\u003cli\u003eEnable Pin: Pull HIGH (5V) to turn heater OFF\u003c\/li\u003e\n\u003cli\u003eWarm-Up Time: ≥ 1 second before readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eOperating Temperature: -30 °C to +85 °C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity: 5 – 95% RH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePhysical Attributes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eDimensions: 20 × 13 × 3.4 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 1 g\u003c\/li\u003e\n\u003cli\u003eUltra-compact MEMS gas sensor module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eIndoor air quality monitoring\u003c\/li\u003e\n\u003cli\u003eCarbon monoxide detection\u003c\/li\u003e\n\u003cli\u003eNatural gas leakage detection\u003c\/li\u003e\n\u003cli\u003eBreath checker devices\u003c\/li\u003e\n\u003cli\u003eEarly fire detection systems\u003c\/li\u003e\n\u003cli\u003eEducational and experimental projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePackage Includes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds ls-n\"\u003e\n\u003cli\u003e1 × MiCS-5524 Gas Sensor Detection Module\u003c\/li\u003e\n\u003cli\u003e1 × Header Set (not soldered)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KitsGuru","offers":[{"title":"Default Title","offer_id":48615363903740,"sku":"KG1334","price":1352.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/20251224_1141_EnhancedProductImage_remix_01kd7fqcskf6sb1srpvrrr6418.jpg?v=1767611386","url":"https:\/\/kitsguru.com\/products\/mics-5524-co-h2-ch4-gas-sensor-detection-module","provider":"KitsGuru","version":"1.0","type":"link"}