{"product_id":"xkc-y26a-pnp-dc-24v-non-contact-liquid-level-sensor","title":"24V DC XKC-Y26A-PNP Thin-Tube Liquid Level Detection Sensor – PNP Output","description":"\u003cdiv class=\"product_info\"\u003e\n\u003ch2 class=\"sing--sub-heading\"\u003e\u003cspan style=\"font-size: 18.72px;\"\u003e 24V DC XKC-Y26A-PNP Thin-Tube Liquid Level Detection Sensor – PNP Output \u003c\/span\u003e\u003c\/h2\u003e\nThe \u003cstrong\u003eXKC-Y26A-PNP 24V\u003c\/strong\u003e is a \u003cstrong\u003ethin-tube non-contact capacitive liquid level sensor\u003c\/strong\u003e designed to detect the presence of liquid inside \u003cstrong\u003esmall-diameter non-metallic pipes\u003c\/strong\u003e. The sensor mounts externally around the pipe using its integrated spring-clip mechanism and detects liquid through the pipe wall without making direct contact with the liquid. \u003cbr\u003e\u003cbr\u003eThis model operates from a \u003cstrong\u003e24V DC power supply\u003c\/strong\u003e and provides a \u003cstrong\u003ePNP transistor output interface\u003c\/strong\u003e. It is suitable for liquid pipelines, water purification equipment, automatic filling systems, industrial automation equipment, PLC systems and liquid level monitoring applications.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eNon-contact liquid detection through non-metallic pipes\u003c\/li\u003e\n\u003cli\u003e24V DC operation\u003c\/li\u003e\n\u003cli\u003ePNP transistor output interface\u003c\/li\u003e\n\u003cli\u003eSuitable for thin non-metallic pipelines\u003c\/li\u003e\n\u003cli\u003eSuitable for approximately 5mm to 10mm pipe outer diameter\u003c\/li\u003e\n\u003cli\u003eMaximum pipe outer diameter approximately 11mm\u003c\/li\u003e\n\u003cli\u003eIntegrated spring-clip pipe mounting design\u003c\/li\u003e\n\u003cli\u003eNo direct contact between sensor and liquid\u003c\/li\u003e\n\u003cli\u003eEasy installation without cutting or drilling the pipe\u003c\/li\u003e\n\u003cli\u003eAdjustable sensing sensitivity\u003c\/li\u003e\n\u003cli\u003eSuitable for cold, hot and boiling liquid detection\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity and stable sensing performance\u003c\/li\u003e\n\u003cli\u003eStrong anti-interference capability\u003c\/li\u003e\n\u003cli\u003ePure electronic non-mechanical sensing structure\u003c\/li\u003e\n\u003cli\u003ePC V0 fire-retardant housing\u003c\/li\u003e\n\u003cli\u003eIP67 waterproof construction\u003c\/li\u003e\n\u003cli\u003eCE certified\u003c\/li\u003e\n\u003cli\u003eRoHS 2.0 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWorking Principle\u003c\/h3\u003e\nThe \u003cstrong\u003eXKC-Y26A-PNP\u003c\/strong\u003e operates using the \u003cstrong\u003ecapacitive sensing principle\u003c\/strong\u003e. When no liquid is present close to the sensing section, the sensor maintains its normal static capacitance. When liquid inside the pipe reaches the sensing point, additional parasitic capacitance is introduced. \u003cbr\u003e\u003cbr\u003eThe internal signal-processing circuit detects the capacitance variation and converts it into an electrical control signal. When the change exceeds the sensing threshold, the sensor determines that liquid is present and switches the \u003cstrong\u003ePNP output\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eItem Type: Thin-Tube Non-Contact Liquid Level Sensor\u003c\/li\u003e\n\u003cli\u003eSeries: XKC-Y26A\u003c\/li\u003e\n\u003cli\u003eModel: XKC-Y26A-PNP\u003c\/li\u003e\n\u003cli\u003eSensing Principle: Capacitive sensing\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: DC 24V\u003c\/li\u003e\n\u003cli\u003eOutput Type: PNP Transistor Output\u003c\/li\u003e\n\u003cli\u003eApplicable Pipe Outer Diameter: Approx. 5mm to 10mm\u003c\/li\u003e\n\u003cli\u003eMaximum Pipe Outer Diameter: Approx. 11mm\u003c\/li\u003e\n\u003cli\u003eLiquid Level Accuracy: ±1.5mm\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20°C to 105°C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC V0 Fire-Retardant Material\u003c\/li\u003e\n\u003cli\u003eWaterproof Rating: IP67\u003c\/li\u003e\n\u003cli\u003eSafety Certification: CE\u003c\/li\u003e\n\u003cli\u003eEnvironmental Certification: RoHS 2.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eMechanical Drawing \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/drawing_7f6ce29b-424f-4d39-8ab6-cfaa117a6588.jpg?v=1788417089\" alt=\"XKC-Y26A-PNP 24V Thin-Tube Liquid Level Sensor Mechanical Drawing and Dimensions\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eMechanical Dimensions\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eSensor Body Length: Approx. 34.4mm\u003c\/li\u003e\n\u003cli\u003eSensor Body Width: Approx. 20mm\u003c\/li\u003e\n\u003cli\u003eSensor Body Height: Approx. 13.6mm\u003c\/li\u003e\n\u003cli\u003eOverall Height Including Clip: Approx. 24.9mm\u003c\/li\u003e\n\u003cli\u003eCable Length: Approx. 500mm\u003c\/li\u003e\n\u003cli\u003eIntegrated Spring-Clip Pipe Holder\u003c\/li\u003e\n\u003cli\u003eBuilt-In Sensitivity Adjustment Control\u003c\/li\u003e\n\u003cli\u003eBuilt-In Indicator Light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eInstallation Method\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/installation_method_73df911d-e0e0-48e0-a622-452d3e31c077.jpg?v=1788417129\" alt=\"XKC-Y26A-PNP 24V Thin-Tube Liquid Level Sensor Installation Method\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eInstallation Procedure\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eCarefully pull open the spring clips\u003c\/li\u003e\n\u003cli\u003ePlace the liquid pipe between the two spring clips\u003c\/li\u003e\n\u003cli\u003eRelease the clips so that the sensor securely grips the pipe\u003c\/li\u003e\n\u003cli\u003eEnsure the sensing section remains in close contact with the pipe\u003c\/li\u003e\n\u003cli\u003ePosition the sensor at the required liquid-level detection point\u003c\/li\u003e\n\u003cli\u003eRecommended pipe outer diameter is approximately 5mm to 10mm\u003c\/li\u003e\n\u003cli\u003eMaximum pipe outer diameter should not exceed approximately 11mm\u003c\/li\u003e\n\u003cli\u003eDo not open the spring clip beyond approximately 60°\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eAfter Installation\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/after_installation.jpg?v=1788417165\" alt=\"XKC-Y26A-PNP 24V Thin-Tube Liquid Level Sensor After Installation\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\" style=\"text-align: left;\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eSensitivity Adjustment\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eUse a small screwdriver to adjust sensing sensitivity\u003c\/li\u003e\n\u003cli\u003eRotate counterclockwise to increase sensitivity\u003c\/li\u003e\n\u003cli\u003eRotate clockwise to decrease sensitivity\u003c\/li\u003e\n\u003cli\u003ePerform sensitivity adjustment after installing the sensor on the actual pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/sensity_adjustment.jpg?v=1788416998\" alt=\"XKC-Y26A-PNP 24V Thin-Tube Liquid Level Sensor Sensitivity Adjustment\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePipe Diameter Requirement\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eRecommended Pipe Outer Diameter: Approx. 5mm to 10mm\u003c\/li\u003e\n\u003cli\u003eMaximum Pipe Outer Diameter: Approx. 11mm\u003c\/li\u003e\n\u003cli\u003eDesigned for thin non-metallic pipelines\u003c\/li\u003e\n\u003cli\u003eEnsure the sensing clip fits securely around the pipe\u003c\/li\u003e\n\u003cli\u003eEnsure proper contact between the sensing section and pipe surface\u003c\/li\u003e\n\u003cli\u003eAvoid direct installation on metallic pipes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePNP Output Interface\u003c\/h3\u003e\nThe \u003cstrong\u003eXKC-Y26A-PNP 24V\u003c\/strong\u003e provides a \u003cstrong\u003ePNP transistor output\u003c\/strong\u003e intended for use with compatible PLC inputs, industrial controllers and automation systems. \u003cbr\u003e\u003cbr\u003eThe connected controller should support a \u003cstrong\u003ePNP sourcing-type sensor signal\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePNP Wiring Diagram\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003c!-- Insert dedicated XKC-Y26A-PNP 24V wiring diagram here --\u003e \u003cstrong\u003eXKC-Y26A-PNP 24V Specific Wiring Diagram Required\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/pnp.jpg?v=1788419625\" alt=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWire Connection\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrown Wire – VCC:\u003c\/strong\u003e Power supply positive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlue Wire – GND:\u003c\/strong\u003e Power supply negative \/ 0V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYellow Wire – OUT:\u003c\/strong\u003e PNP signal output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack Wire – MODE:\u003c\/strong\u003e Output mode selection wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eOperating Temperature Range: -20°C to 105°C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eLiquid Level Accuracy: ±1.5mm\u003c\/li\u003e\n\u003cli\u003eApplicable Pipe Outer Diameter: Approx. 5mm to 10mm\u003c\/li\u003e\n\u003cli\u003eMaximum Pipe Outer Diameter: Approx. 11mm\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC V0 Fire-Retardant Material\u003c\/li\u003e\n\u003cli\u003eWaterproof Performance: IP67\u003c\/li\u003e\n\u003cli\u003eSafety Certification: CE\u003c\/li\u003e\n\u003cli\u003eEnvironmental Certification: RoHS 2.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eInstallation \u0026amp; Usage Notes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eInstall only on suitable non-metallic pipes\u003c\/li\u003e\n\u003cli\u003eMake sure the sensing section fits securely against the pipe surface\u003c\/li\u003e\n\u003cli\u003eDo not force the spring clips beyond approximately 60°\u003c\/li\u003e\n\u003cli\u003eKeep the sensing area clean and free from debris\u003c\/li\u003e\n\u003cli\u003eKeep metallic objects away from the sensing section where possible\u003c\/li\u003e\n\u003cli\u003eAvoid strong impacts and mechanical damage\u003c\/li\u003e\n\u003cli\u003eAvoid installation close to excessive heat sources\u003c\/li\u003e\n\u003cli\u003eProtect the sensor from prolonged direct sunlight and direct rain during outdoor use\u003c\/li\u003e\n\u003cli\u003eAdjust sensitivity after installation if necessary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eThin water pipes\u003c\/li\u003e\n\u003cli\u003eSmall-diameter liquid pipelines\u003c\/li\u003e\n\u003cli\u003eWater dispensers\u003c\/li\u003e\n\u003cli\u003eWater purification systems\u003c\/li\u003e\n\u003cli\u003eAutomatic filling equipment\u003c\/li\u003e\n\u003cli\u003eLiquid dispensing systems\u003c\/li\u003e\n\u003cli\u003eLiquid level alarm systems\u003c\/li\u003e\n\u003cli\u003eIndustrial liquid monitoring\u003c\/li\u003e\n\u003cli\u003ePLC automation systems\u003c\/li\u003e\n\u003cli\u003eAutomatic liquid-level control systems\u003c\/li\u003e\n\u003cli\u003eIndustrial control equipment\u003c\/li\u003e\n\u003cli\u003eHome appliances\u003c\/li\u003e\n\u003cli\u003eIoT liquid monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eTroubleshooting\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/truobshot.jpg?v=1788417634\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePackage Includes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds ls-n\"\u003e\n\u003cli\u003e1 × 24V DC XKC-Y26A-PNP Thin-Tube Liquid Level Detection Sensor – PNP Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KitsGuru","offers":[{"title":"Default Title","offer_id":51208907915516,"sku":"KG1395","price":849.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/XKC-Y26A-PNP-24V-Detector.png?v=1788413255","url":"https:\/\/kitsguru.com\/products\/xkc-y26a-pnp-dc-24v-non-contact-liquid-level-sensor","provider":"KitsGuru","version":"1.0","type":"link"}