{"product_id":"xkc-y26s-pnp-dc-24v-non-contact-liquid-level-sensor","title":"XKC-Y26S-PNP 24V Non-Contact Water\/Liquid Level Sensor – PNP Output","description":"\u003cdiv class=\"product_info\"\u003e\n\u003ch2 class=\"sing--sub-heading\"\u003e\u003cspan style=\"font-size: 18.72px;\"\u003e XKC-Y26S-PNP 24V Non-Contact Water\/Liquid Level Sensor – PNP Output \u003c\/span\u003e\u003c\/h2\u003e\nThe \u003cstrong\u003eXKC-Y26S-PNP 24V\u003c\/strong\u003e is a \u003cstrong\u003enon-contact capacitive water and liquid level sensor\u003c\/strong\u003e designed to detect liquid through the outer wall of \u003cstrong\u003enon-metallic containers and pipes\u003c\/strong\u003e. It is installed externally and detects the presence of liquid without requiring direct contact with the medium, making it suitable for sealed tanks, water containers, non-metallic pipes, liquid storage systems, industrial equipment, and automation applications. \u003cbr\u003e\u003cbr\u003eThis model operates from a \u003cstrong\u003e24V DC power supply\u003c\/strong\u003e and provides a \u003cstrong\u003ePNP output interface\u003c\/strong\u003e. Its non-contact sensing design helps reduce contamination, corrosion, leakage, and maintenance issues associated with conventional contact-type liquid level sensors.\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eNon-contact water and liquid level detection\u003c\/li\u003e\n\u003cli\u003eDetects liquid through non-metallic container walls\u003c\/li\u003e\n\u003cli\u003eNo direct contact between sensor and liquid\u003c\/li\u003e\n\u003cli\u003e24V DC operating voltage\u003c\/li\u003e\n\u003cli\u003ePNP transistor output interface\u003c\/li\u003e\n\u003cli\u003eLow current consumption of ≤ 5mA\u003c\/li\u003e\n\u003cli\u003eMaximum output current up to 100mA\u003c\/li\u003e\n\u003cli\u003e500ms response time\u003c\/li\u003e\n\u003cli\u003eLevel accuracy of ±1.5mm\u003c\/li\u003e\n\u003cli\u003eAdjustable sensing sensitivity\u003c\/li\u003e\n\u003cli\u003eSuitable for non-metallic tanks, containers and pipes\u003c\/li\u003e\n\u003cli\u003eSuitable for pipe diameters of 10mm and above\u003c\/li\u003e\n\u003cli\u003eExternal mounting – no drilling of the container required\u003c\/li\u003e\n\u003cli\u003ePC + ABS V0 fire-retardant housing\u003c\/li\u003e\n\u003cli\u003eIP67 waterproof protection\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range\u003c\/li\u003e\n\u003cli\u003eCE certified\u003c\/li\u003e\n\u003cli\u003eRoHS 2.0 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWorking Principle\u003c\/h3\u003e\nThe sensor operates using the \u003cstrong\u003ecapacitive sensing principle\u003c\/strong\u003e. When no liquid is present near the sensing surface, the sensor maintains its normal capacitance level. When the liquid reaches the sensing position, the electrical capacitance detected through the non-metallic container wall changes. \u003cbr\u003e\u003cbr\u003eThe internal control circuit detects this capacitance variation and converts it into an electrical signal. When the detected change reaches the set threshold, the sensor determines that liquid is present and switches the \u003cstrong\u003ePNP output\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eItem Type: Non-Contact Water \/ Liquid Level Sensor\u003c\/li\u003e\n\u003cli\u003eSeries: XKC-Y26S\u003c\/li\u003e\n\u003cli\u003eModel: XKC-Y26S-PNP 24V\u003c\/li\u003e\n\u003cli\u003eOperating Principle: Capacitive sensing\u003c\/li\u003e\n\u003cli\u003eInput Voltage: DC 24V\u003c\/li\u003e\n\u003cli\u003eOutput Type: PNP output interface\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: ≤ 5mA\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current: ≤ 100mA\u003c\/li\u003e\n\u003cli\u003eResponse Time: 500ms\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20°C to 105°C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eLevel Accuracy: ±1.5mm\u003c\/li\u003e\n\u003cli\u003eApplicable Pipe Diameter: ≥ 10mm\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC + ABS V0 fire-retardant material\u003c\/li\u003e\n\u003cli\u003eWaterproof Rating: IP67\u003c\/li\u003e\n\u003cli\u003eSafety Certification: CE\u003c\/li\u003e\n\u003cli\u003eEnvironmental Certification: RoHS 2.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eMechanical Drawing \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/Mechanical_drawing.png?v=1788331579\" alt=\"XKC-Y26S-PNP 24V Non-Contact Liquid Level Sensor Mechanical Drawing and Dimensions\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eGap Requirement Between Sensor and Container Wall\u003c\/h3\u003e\nThe sensing surface should be attached \u003cstrong\u003etightly to the outer wall of the container\u003c\/strong\u003e. Use AB glue or another durable adhesive to securely attach the sensor to the container wall. \u003cbr\u003e\u003cbr\u003eThe gap between the sensor sensing surface and the container wall should be \u003cstrong\u003eless than 0.5mm\u003c\/strong\u003e. For optimum sensing sensitivity and reliable liquid detection, \u003cstrong\u003eno gap is recommended\u003c\/strong\u003e between the sensor and container wall.\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eGap Requirement Between Sensor and Container Wall Drawing\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/gap.png?v=1788331680\" alt=\"XKC-Y26S-PNP 24V Sensor Gap Requirement Diagram\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFlat Container Installation\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/installation_diagram.png?v=1788331895\" alt=\"XKC-Y26S-PNP 24V Flat Non-Metallic Container Installation Diagram\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003cdiv style=\"text-align: center;\" class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePipe Installation\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/ChatGPT_Image_Sep_2_2026_11_47_18_AM_4.png?v=1788331826\" alt=\"XKC-Y26S-PNP 24V Non-Metallic Pipe Installation Diagram\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\" style=\"text-align: left;\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eSensitivity Adjustment\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eUse a small screwdriver to adjust the sensing sensitivity\u003c\/li\u003e\n\u003cli\u003eRotate counterclockwise to increase sensitivity\u003c\/li\u003e\n\u003cli\u003eRotate clockwise to decrease sensitivity\u003c\/li\u003e\n\u003cli\u003eAdjust sensitivity after installing the sensor on the actual tank, container or pipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/Sensitibity_adjustment.png?v=1788331263\" alt=\"XKC-Y26S-PNP 24V Liquid Level Sensor Sensitivity Adjustment\" style=\"margin-bottom: 16px; float: none;\" loading=\"lazy\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWall Thickness \u0026amp; Pipe Diameter Selection\u003c\/h3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/table.png?v=1788331326\" alt=\"XKC-Y26S-PNP 24V Wall Thickness and Pipe Diameter Selection Table\" loading=\"lazy\"\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWall Thickness Selection Guide\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003ePipe Diameter D ≥ 100mm: Wall Thickness 20 ± 2mm\u003c\/li\u003e\n\u003cli\u003ePipe Diameter 100mm \u0026gt; D ≥ 80mm: Wall Thickness 15 ± 2mm\u003c\/li\u003e\n\u003cli\u003ePipe Diameter 80mm \u0026gt; D ≥ 60mm: Wall Thickness 12 ± 1.5mm\u003c\/li\u003e\n\u003cli\u003ePipe Diameter 60mm \u0026gt; D ≥ 40mm: Wall Thickness 7 ± 1.0mm\u003c\/li\u003e\n\u003cli\u003ePipe Diameter 40mm \u0026gt; D ≥ 30mm: Wall Thickness 5 ± 1.0mm\u003c\/li\u003e\n\u003cli\u003ePipe Diameter 30mm \u0026gt; D ≥ 20mm: Wall Thickness 3 ± 1.0mm\u003c\/li\u003e\n\u003cli\u003ePipe Diameter 20mm \u0026gt; D ≥ 10mm: Wall Thickness 1.5 ± 0.5mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePNP Output \u0026amp; Wiring\u003c\/h3\u003e\nThe \u003cstrong\u003eXKC-Y26S-PNP 24V\u003c\/strong\u003e uses a PNP transistor output. In a PNP configuration, the sensor provides a positive output signal when the output transistor is switched. \u003cbr\u003e\u003cbr\u003eAlways connect the sensor according to the dedicated \u003cstrong\u003eXKC-Y26S-PNP 24V wiring diagram\u003c\/strong\u003e supplied with the product.\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/diagram2.png?v=1788331509\" alt=\"\"\u003e\u003cbr\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003c!-- Insert XKC-Y26S-PNP 24V Wiring Diagram Image Here --\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eEnvironmental \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eOperating Temperature Range: -20°C to 105°C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eLevel Accuracy: ±1.5mm\u003c\/li\u003e\n\u003cli\u003eMinimum Applicable Pipe Diameter: 10mm\u003c\/li\u003e\n\u003cli\u003eMaximum Recommended Wall Thickness: Up to 20 ± 2mm depending on pipe diameter\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC + ABS V0 fire-retardant material\u003c\/li\u003e\n\u003cli\u003eWaterproof Performance: IP67\u003c\/li\u003e\n\u003cli\u003eSafety Certification: CE\u003c\/li\u003e\n\u003cli\u003eEnvironmental Certification: RoHS 2.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eInstallation Instructions\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eInstall the sensor externally on a non-metallic container or pipe\u003c\/li\u003e\n\u003cli\u003ePosition the sensing surface at the required liquid level detection point\u003c\/li\u003e\n\u003cli\u003eEnsure the sensing surface has full contact with the container or pipe wall\u003c\/li\u003e\n\u003cli\u003eKeep the installation gap below 0.5mm\u003c\/li\u003e\n\u003cli\u003eFor optimum performance, installation without any gap is recommended\u003c\/li\u003e\n\u003cli\u003eUse a durable adhesive for installation on flat container surfaces\u003c\/li\u003e\n\u003cli\u003eUse suitable plastic cable ties for installation on pipes\u003c\/li\u003e\n\u003cli\u003eAdjust the sensitivity after final installation if required\u003c\/li\u003e\n\u003cli\u003eDo not install the sensing surface on a metallic container wall\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eWater tanks and reservoirs\u003c\/li\u003e\n\u003cli\u003eLiquid storage containers\u003c\/li\u003e\n\u003cli\u003ePlastic water tanks\u003c\/li\u003e\n\u003cli\u003eWater dispensers\u003c\/li\u003e\n\u003cli\u003eIndustrial liquid level monitoring\u003c\/li\u003e\n\u003cli\u003eNon-metallic pipelines\u003c\/li\u003e\n\u003cli\u003eAutomatic filling systems\u003c\/li\u003e\n\u003cli\u003eLiquid level alarm systems\u003c\/li\u003e\n\u003cli\u003eWater treatment equipment\u003c\/li\u003e\n\u003cli\u003eHome appliances\u003c\/li\u003e\n\u003cli\u003eIndustrial automation equipment\u003c\/li\u003e\n\u003cli\u003ePLC control systems\u003c\/li\u003e\n\u003cli\u003eFactory automation systems\u003c\/li\u003e\n\u003cli\u003eIoT liquid level monitoring projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePackage Includes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds ls-n\"\u003e\n\u003cli\u003e1 × XKC-Y26S-PNP 24V Non-Contact Water\/Liquid Level Sensor – PNP Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KitsGuru","offers":[{"title":"Default Title","offer_id":51208851325180,"sku":"KG1385","price":699.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/XKC-Y26S-24V-PNP-Sensor.png?v=1788412312","url":"https:\/\/kitsguru.com\/products\/xkc-y26s-pnp-dc-24v-non-contact-liquid-level-sensor","provider":"KitsGuru","version":"1.0","type":"link"}