{"product_id":"xkc-y29a-npn-dc-12-24v-non-contact-liquid-level-sensor","title":"12-24V DC XKC-Y29A Wall-Mounted Liquid Level Sensor – Non-Contact, NPN Output","description":"\n\u003cdiv class=\"product_info\"\u003e\n\u003ch2 class=\"sing--sub-heading\"\u003e\n\u003cspan style=\"font-size: 18.72px;\"\u003e\nXKC-Y29A-NPN Wall-Mount Non-Contact Liquid Level Sensor – DC 12-24V NPN Output\n\u003c\/span\u003e\n\u003c\/h2\u003e\n\nThe \u003cstrong\u003eXKC-Y29A-NPN Wall-Mount Non-Contact Liquid Level Sensor\u003c\/strong\u003e detects liquid levels through the walls of compatible \u003cstrong\u003enon-metallic containers\u003c\/strong\u003e without direct contact with their contents. Designed for external mounting on plastic, glass and ceramic containers, its electronic sensing system supports liquid-level monitoring in industrial, water-handling and automated equipment.\n\n\u003cbr\u003e\u003cbr\u003e\n\nOperating on a \u003cstrong\u003eDC 12-24V power supply\u003c\/strong\u003e, this sensor features an \u003cstrong\u003eNPN open-collector output\u003c\/strong\u003e for integration with compatible controllers and industrial automation systems. Its sensitivity can be calibrated for different container materials and wall thicknesses. It supports sensing through container walls up to \u003cstrong\u003e10mm thick\u003c\/strong\u003e, with a specified \u003cstrong\u003e±3mm liquid-level accuracy\u003c\/strong\u003e for the Y29A family.\n\n\u003cbr\u003e\u003cbr\u003e\n\nThe sensor features strong resistance to electromagnetic interference, electrical protection against reverse polarity, short circuits, overcurrent and overvoltage, and a \u003cstrong\u003ePC-V0 flame-retardant housing with IP67 protection\u003c\/strong\u003e. It is designed to detect cold, hot and boiling liquids through suitable container walls, while the sensor itself must remain within its specified operating temperature range.\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eNon-contact liquid level detection through non-metallic container walls\u003c\/li\u003e\n\u003cli\u003eSuitable for plastic, glass and ceramic containers\u003c\/li\u003e\n\u003cli\u003eDC 12-24V operating voltage\u003c\/li\u003e\n\u003cli\u003eNPN open-collector signal output\u003c\/li\u003e\n\u003cli\u003eAdjustable sensitivity for different installation requirements\u003c\/li\u003e\n\u003cli\u003eSupports container wall thicknesses up to 10mm\u003c\/li\u003e\n\u003cli\u003eLiquid-level accuracy of ±3mm\u003c\/li\u003e\n\u003cli\u003eStrong resistance to electromagnetic and common-mode interference\u003c\/li\u003e\n\u003cli\u003eReverse-polarity, short-circuit, overcurrent and overvoltage protection\u003c\/li\u003e\n\u003cli\u003eCan sense liquids, powders and particulate materials under suitable conditions\u003c\/li\u003e\n\u003cli\u003eNon-mechanical electronic sensing design\u003c\/li\u003e\n\u003cli\u003eIP67 protection and PC-V0 flame-retardant housing\u003c\/li\u003e\n\u003cli\u003eCompact external wall-mount design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eItem Type: Wall-Mount Non-Contact Liquid Level Sensor\u003c\/li\u003e\n\u003cli\u003eModel No.: XKC-Y29A-NPN\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: DC 12-24V\u003c\/li\u003e\n\u003cli\u003eOutput Type: NPN Open Collector\u003c\/li\u003e\n\u003cli\u003eDetection Method: Non-Contact Capacitive Sensing\u003c\/li\u003e\n\u003cli\u003eMaximum Container Wall Thickness: 10mm\u003c\/li\u003e\n\u003cli\u003eLiquid Level Accuracy: ±3mm\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -25°C to 85°C\u003c\/li\u003e\n\u003cli\u003eOperating Humidity: 30%-80% (Non-Condensing)\u003c\/li\u003e\n\u003cli\u003eStandard Cable Length: 500mm (±10mm)\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC-V0 Flame-Retardant\u003c\/li\u003e\n\u003cli\u003eWaterproof Rating: IP67\u003c\/li\u003e\n\u003cli\u003eSafety Certification: CE\u003c\/li\u003e\n\u003cli\u003eEnvironmental Compliance: RoHS 2.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eApplications\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eExternal liquid-level monitoring of non-metallic tanks and containers\u003c\/li\u003e\n\u003cli\u003eWater dispensing and water treatment equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial liquid-level alarms and automation\u003c\/li\u003e\n\u003cli\u003eFood-processing equipment with compatible non-metallic containers\u003c\/li\u003e\n\u003cli\u003eMedical and laboratory fluid-handling equipment where suitable\u003c\/li\u003e\n\u003cli\u003eLiquid-level detection through plastic, glass and ceramic walls\u003c\/li\u003e\n\u003cli\u003ePowder and particulate presence sensing in suitable containers\u003c\/li\u003e\n\u003cli\u003eNPN-compatible industrial controller applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\" style=\"text-align: center;\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eDrawing\u003c\/h3\u003e\n\u003cp\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/xkc-y29a-v-dimension-drawing.png?v=1790407606\" alt=\"XKC-Y29A Wall-Mount Liquid Level Sensor Dimension Drawing\"\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\" style=\"text-align: center;\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003eWiring Diagram\u003c\/h3\u003e\n\u003cp\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/xkc-y29a-v-wiring-diagram.png?v=1790407622\" alt=\"XKC-Y29A-V Reference Wiring Diagram\"\u003e\n\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\nNote: The diagram illustrates the Y29A-V configuration.\nConfirm the NPN model's wire connections and output\noperation before installation.\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePhysical Attributes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds\"\u003e\n\u003cli\u003eHousing Type: Flat External-Mount Sensor\u003c\/li\u003e\n\u003cli\u003eHousing Material: PC-V0 Flame-Retardant\u003c\/li\u003e\n\u003cli\u003eOverall Body Length: 51.40mm\u003c\/li\u003e\n\u003cli\u003eOverall Body Width: 29.50mm\u003c\/li\u003e\n\u003cli\u003eOverall Thickness Shown: 8.80mm\u003c\/li\u003e\n\u003cli\u003eHousing Side Thickness Shown: 7.80mm\u003c\/li\u003e\n\u003cli\u003eMounting Hole Diameter: Ø2.30mm\u003c\/li\u003e\n\u003cli\u003eMounting Hole Centre Spacing: 45.50mm × 23.60mm\u003c\/li\u003e\n\u003cli\u003eConnector Type: XH2.54-4P\u003c\/li\u003e\n\u003cli\u003eStandard Cable Length: 500mm (±10mm)\u003c\/li\u003e\n\u003cli\u003eWaterproof Rating: IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product_info\"\u003e\n\u003ch3 class=\"sing--sub-heading\"\u003ePackage Includes\u003c\/h3\u003e\n\u003cdiv id=\"p_info\"\u003e\n\u003cul class=\"pro-ds ls-n\"\u003e\n\u003cli\u003e1 × XKC-Y29A-NPN Wall-Mount Non-Contact Liquid Level Sensor – DC 12-24V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"KitsGuru","offers":[{"title":"Default Title","offer_id":51208937177340,"sku":"KG1431","price":1199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/2130\/4757\/files\/XKC-Y29A-NPN-Wall-Sensor.png?v=1788414260","url":"https:\/\/kitsguru.com\/products\/xkc-y29a-npn-dc-12-24v-non-contact-liquid-level-sensor","provider":"KitsGuru","version":"1.0","type":"link"}