12V/24V/36V/48V 8-70V LCD Acid Lead Lithium Battery Capacity Indicator Digital Voltmeter
Voltage range: 8-70V, products will display based on the voltage value, voltage fluctuations, the power meter will be followed as the voltage fluctuation! (Comes with reverse polarity protection, can be guaranteed use effectively )
The product is suitable for lead-acid 12V, 24V, 36V, 48V (can be changed via key, specific please see setup instructions as below)
The product is suitable for 3.7V lithium series multi-platform, 3 string, 4 string, 5 string, 6 string, 7 string and 8 string 9 string 10 string 11 string 12 string 13 string 14 string 15 string (can be changed via key, detail information please see as below)
Battery specifications:
P=lead acid, L=lithium battery, F=lithium iron phosphate battery
Single string battery nominal voltage:
Lead acid = 12V, lithium battery = 3.7V, lithium iron phosphate = 3.2V
Special Function Setting (requires electric iron, you must power off setting, electric iron must be grounded)
A point connection, the backlight will be automatically shut down if delay10 seconds , the voltage fluctuation will automatic wake-up exceeds 0.3V / 0.5 seconds.
B point connection, lithium choose 3-4.1V curve (lithium professionals)
12V/24V/36V/48V 8-70V LCD Acid Lead Lithium Battery Capacity Indicator Digital Voltmeter
Available:Out of Stock
- Product SKU: KG792
₹ 990
₹ 999

Specification
Description
Power, Voltage, Close, are the key to the cycle.Voltage range: 8-70V, products will display based on the voltage value, voltage fluctuations, the power meter will be followed as the voltage fluctuation! (Comes with reverse polarity protection, can be guaranteed use effectively )
The product is suitable for lead-acid 12V, 24V, 36V, 48V (can be changed via key, specific please see setup instructions as below)
The product is suitable for 3.7V lithium series multi-platform, 3 string, 4 string, 5 string, 6 string, 7 string and 8 string 9 string 10 string 11 string 12 string 13 string 14 string 15 string (can be changed via key, detail information please see as below)
Battery specifications:
P=lead acid, L=lithium battery, F=lithium iron phosphate battery
Single string battery nominal voltage:
Lead acid = 12V, lithium battery = 3.7V, lithium iron phosphate = 3.2V
Setup steps
- Press and hold the setting button to power the battery, enter the setting interface
- Short press the setting button to select the battery specification (P=lead acid L=lithium battery F=lithium iron phosphate battery)
- Short press the function key to select the number of battery strings (the setting key is increased, the function key is reduced)
- After setting it, you can re-power it.
S1: %/V 2 seconds in turn display
S2: 10 second delay off
S3: Turn on the backlight
S4: Turn on LOGO
S5: Battery curve selection
Instructions
- Press and hold switch on the product, power on, automatically select the interface ( please follow as the code corresponds blow)
- Select your battery type after corresponding, for example 3 series lithium battery, you need to enter the selection screen, press the key point to L3 interface, then off, re-energized, choose success, such as the need to set 12V lead-acid batteries, the key point press to P12V interface, power, re-energized, both choose success
- Instruments can be used if you Select successful . . Meter shows the power interface, tap switch, switch to voltage interface, click the switch, turn off the meter. cycle shown as the code corresponds
- Code: Suitable for
L3: 3 string lithium
L4: 4 string lithium
L5: 5 string lithium
L6: 6 string lithium
L7: 7 string lithium
L8: 8 string lithium
L9: 9 string lithium
L10: 10 string lithium
L11: 11 string lithium
L12: 12 string lithium
L13: 13 string lithium
L14: 14 string lithium
P12V: 12V lead-acid
P24V: 24V lead-acid
P36V: 36V lead-acid
P48V: 48V lead-acid
Special Function Setting (requires electric iron, you must power off setting, electric iron must be grounded)
A point connection, the backlight will be automatically shut down if delay10 seconds , the voltage fluctuation will automatic wake-up exceeds 0.3V / 0.5 seconds.
B point connection, lithium choose 3-4.1V curve (lithium professionals)