XKC-Y25 5-12V Non-Contact Liquid Level Sensor with NPN Output
Review: 5 - "A masterpiece of literature" by John Doe, written onMay 4, 20020
Great
-22%
XKC-Y25 NPN Liquid Sensor
5-12V Level Detection Sensor
Non-Contact NPN Water Switch

XKC-Y25 5-12V Non-Contact Liquid Level Sensor with NPN Output

Available:In Stock
  • Product SKU: KG1435
Wishlist
₹ 499 ₹ 648
Available offers
Best Rates

on Express Shipping – Hurry! Shipping starts from Rs69.

Tc
Free Shipping Offer -

Avail free shipping on all orders above Rs999.

Tc
Volume Discounts-

Buy More Save More! Discounts upto 20%. Contact us

Special Bulk Discounts

for colleges, Schools, Companies & resellers Contact us

Cash on Delivery

Available above Rs 499

Tc
Highlights
  • Original, High Quality
  • KitsGuru Warranty
  • Non-contact liquid level detection
  • Operating Voltage: DC 5–12V
  • NPN Output
  • Easy external installation
  • Ideal for water level monitoring
Services
  • Email Support
  • Video Support to be purchased separately
Easy Payment Options
  • Netbanking
  • Debit/Credit cards
  • Cash on Delivery
  • E-wallets/UPI
How Fast We Ship
International Shipping
Available

  Need Volume Discounts? Deals are specially designed for you. Click here

  Need Customization? Provide us more details Click here

🏠 Warehouse Details:
24 E - 133 Q
Image
Secure

Specification

Description

XKC-Y25 5-12V Non-Contact Liquid Level Sensor with NPN Output

The XKC-Y25 5-12V Non-Contact Liquid Level Sensor with NPN Output detects liquid presence through the walls of compatible non-metallic containers and pipelines without touching the liquid. Its external capacitive sensing design allows monitoring at a selected level on plastic, glass, acrylic and non-absorbent ceramic containers without opening the container.

Operating on a DC 5-12V power supply, this variant provides NPN transistor (sinking) output for connection to a correctly matched controller or switching interface. The Y25 sensor family supports detection through suitable non-metallic walls up to 20mm thick and allows external adhesive or non-metallic bracket mounting.

The compact round sensor uses a non-mechanical detection method and is designed for contact-free sensing of cold, hot and boiling liquids through a suitable container wall. The 5-12V variant is suited to compatible controllers and low-power automation in a good electromagnetic environment. Keep high-power inductive and capacitive loads away from the sensor power bus.

Features

  • True non-contact liquid-level detection through compatible non-metallic walls
  • External mounting without drilling suitable non-metallic containers
  • Suitable for plastic, glass, acrylic and non-absorbent ceramic containers
  • DC 5-12V operating voltage
  • NPN transistor (sinking) for compatible control interfaces
  • Y25 family sensing capability through suitable walls up to 20mm
  • Designed for cold, hot and boiling liquid detection through container walls
  • Non-mechanical electronic sensing design
  • External adhesive or non-metallic bracket installation
  • Compact round sensor housing
  • May detect powders and granules under suitable conditions
  • Suitable for compatible low-power control circuits in good EMC conditions

Technical Details

  • Item Type: Non-Contact Liquid Level Sensor
  • Model No.: XKC-Y25-NPN
  • Operating Voltage: DC 5-12V
  • Output Type: NPN transistor (sinking)
  • Detection Method: External Non-Contact Capacitive Sensing
  • Suitable Container Materials: Plastic, Glass, Acrylic, Non-Absorbent Ceramics
  • Y25 Family Compatible Wall Thickness: Up to 20mm (installation dependent)
  • Mounting Gap: Less than 0.5mm; zero gap preferred
  • Housing Material Shown in Y25 Manual: PC V0 Flame-Retardant
  • Waterproof Rating Shown in Y25 Manual: IP67
  • Cable Length Shown in Shared Drawing: 500mm (±10mm)

Applications

  • High- and low-level monitoring in non-metallic water tanks
  • External liquid detection in plastic and glass containers
  • Water dispensers and fluid-handling equipment
  • Liquid-level alarms and automatic filling systems
  • Monitoring compatible chemical-storage containers
  • Non-metallic pipeline and external standpipe monitoring
  • Low-power NPN-compatible controller and electronic projects
  • Powder or granular-material presence sensing where suitable

Installation Method

XKC-Y25 installation method illustration 1 XKC-Y25 installation method illustration 2 XKC-Y25 installation method illustration 3 XKC-Y25 installation method illustration 4 XKC-Y25 installation method illustration 5

Drawing

XKC-Y25 shared sensor dimensions and connector drawing

Wiring Diagram

XKC-Y25-V wiring diagram supplied for visual reference; not the NPN variant pinout

Wire Connections and Output

  • Power Supply: DC 5-12V
  • Signal Output: NPN transistor (sinking)
  • Connect only to a compatible controller or interface with the appropriate input circuit
  • The Y25-V black MODE wire function and its HIGH/LOW selection must not be assumed for this model
  • The supplied Y25-V wiring illustration is not a verified pinout for this variant
  • Switch off power before wiring; confirm the actual wire colours and terminals for the purchased model

Physical Attributes

  • Housing Type: Compact Round External-Mount Sensor (shared Y25 drawing)
  • Housing Material Shown: PC V0 Flame-Retardant
  • Front Sensor Diameter Shown: Ø28.3mm
  • Rear Housing Diameter Shown: Ø25.5mm
  • Sensor Thickness Shown: 4.5mm
  • Connector Shown: XH2.54-4P (4-Pin)
  • Back-View Horizontal Dimensions Shown: 16.6mm and 12.6mm
  • Cable Length Shown: 500mm (±10mm)
  • Installation Type: External Adhesive or Non-Metallic Bracket Mount
  • Waterproof Rating Shown: IP67

Usage Notes

  • Bond the sensing surface closely to the container wall; keep any gap below 0.5mm, preferably with no gap
  • Do not attach directly to a metal wall; an appropriate non-metallic sensing window or external tube is required
  • Detection of viscous liquids can be affected by residue adhering to container walls
  • For outdoor installation, protect the sensor body from direct sunlight, direct rain runoff and excess heat
  • Use in good EMC conditions; avoid high-power inductive or capacitive loads on the sensor supply bus

Package Includes

  • 1 × XKC-Y25 5-12V Non-Contact Liquid Level Sensor with NPN Output with Cable