XKC-Y25-V Non-Contact Water & Liquid Level Sensor – DC 5-24V Signal Output
Review: 5 - "A masterpiece of literature" by John Doe, written onMay 4, 20020
Great
-22%
XKC-Y25-V Liquid Sensor
5-24V Water Level Detector
Non-Contact Level Sensor

XKC-Y25-V Non-Contact Water & Liquid Level Sensor – DC 5-24V Signal Output

Available:In Stock
  • Product SKU: KG1432
Wishlist
₹ 499 ₹ 648
Available offers
Best Rates

on Express Shipping – Hurry! Shipping starts from Rs69.

Tc
Free Shipping Offer -

Avail free shipping on all orders above Rs999.

Tc
Volume Discounts-

Buy More Save More! Discounts upto 20%. Contact us

Special Bulk Discounts

for colleges, Schools, Companies & resellers Contact us

Cash on Delivery

Available above Rs 499

Tc
Highlights
  • Original, High Quality
  • KitsGuru Warranty
  • Non-contact liquid level detection
  • Operating Voltage: DC 5–24V
  • V-Type Signal Output
  • Easy external installation
  • Ideal for water level monitoring
Services
  • Email Support
  • Video Support to be purchased separately
Easy Payment Options
  • Netbanking
  • Debit/Credit cards
  • Cash on Delivery
  • E-wallets/UPI
How Fast We Ship
International Shipping
Available

  Need Volume Discounts? Deals are specially designed for you. Click here

  Need Customization? Provide us more details Click here

🏠 Warehouse Details:
24 E - 130 Q
Image
Secure

Specification

Description

XKC-Y25-V DC 5-24V Non-Contact Liquid Level Sensor

The XKC-Y25-V Non-Contact Liquid Level Sensor is designed to detect liquid presence through the walls of compatible non-metallic containers and pipelines without touching their contents. Using capacitive sensing and electronic signal processing, it can be mounted externally at a selected liquid-level position without opening a non-metallic tank. It is suitable for plastic, glass, acrylic and non-absorbent ceramic containers.

Operating on a DC 5-24V power supply, this sensor provides a high and low level signal output for connection to compatible control circuits. The black MODE wire selects the output logic: it may be left unconnected or connected to GND, as described in the wiring section. Adjustable sensitivity supports different container materials and wall thicknesses of up to 20mm.

The sensor offers ±1.5mm liquid-level accuracy, a 500ms response time, low current consumption of 5mA or less, and a PC V0 flame-retardant, IP67-rated housing. It can detect cold, hot and boiling liquids through suitable container walls, provided the sensor remains within its specified operating temperature range.

Features

  • True non-contact liquid-level detection through compatible non-metallic walls
  • External installation without drilling a non-metallic container
  • Suitable for plastic, glass, acrylic and non-absorbent ceramic containers
  • DC 5-24V operating voltage
  • High and low level signal output with selectable output logic
  • Adjustable sensitivity using the rear adjustment control
  • Detects through suitable container walls up to 20mm thick
  • Liquid-level accuracy of ±1.5mm
  • 500ms response time and low current consumption of 5mA or less
  • Designed for cold, hot and boiling liquid detection through container walls
  • Strong resistance to electromagnetic, power-frequency and common-mode interference
  • Non-mechanical electronic sensing construction
  • IP67 protection and PC V0 flame-retardant housing
  • May detect powders and granules under suitable conditions

Technical Details

  • Item Type: Non-Contact Liquid Level Sensor
  • Model No.: XKC-Y25-V
  • Operating Voltage: DC 5-24V
  • Output Type: V (High and Low Level Signal)
  • Power Supply Ripple Requirement: ≤200mV
  • Operating Current: ≤5mA
  • Response Time: 500ms
  • Operating Temperature: -20°C to 105°C
  • Operating Humidity: 5%-100%
  • Maximum Compatible Container Wall Thickness: 20mm
  • Liquid-Level Accuracy: ±1.5mm
  • Standard Cable Length: 500mm (±10mm)
  • Wire Connections: Brown - VCC; Yellow - OUT; Blue - GND; Black - MODE (Output Selection)
  • Housing Material: PC V0 Flame-Retardant
  • Waterproof Rating: IP67
  • Safety Certification: CE
  • Environmental Compliance: RoHS 2.0

Applications

  • High- and low-level monitoring in non-metallic water tanks
  • External liquid detection in plastic, glass and acrylic containers
  • Water dispensers and fluid-handling equipment
  • Liquid-level alarms and automatic filling systems
  • Monitoring compatible chemical-storage containers
  • Non-metallic pipeline and external standpipe monitoring
  • Industrial control and compatible MCU-based projects
  • Powder or granular-material presence sensing where suitable

Installation Method

Drawing

Wiring Diagram

Wire Connections and Output Selection

  • Brown: DC 5-24V positive supply (VCC)
  • Blue: Ground / negative supply (GND)
  • Yellow: High and low level signal output (OUT)
  • Black: MODE / output selection
  • Black wire left unconnected: liquid detected = HIGH; no liquid = LOW
  • Black wire connected to GND: liquid detected = LOW; no liquid = HIGH
  • The manual illustrates controller/MCU input, indicator LED and small relay connections. For the illustrated small relay application, the coil current must be 100mA or less.

Physical Attributes

  • Housing Type: Compact Round External-Mount Sensor
  • Housing Material: PC V0 Flame-Retardant
  • Front Sensor Diameter: Ø28.3mm
  • Rear Housing Diameter Shown: Ø25.5mm
  • Sensor Thickness Shown: 4.5mm
  • Connector Type: XH2.54-4P (4-Pin)
  • Back-View Horizontal Dimensions Shown: 16.6mm and 12.6mm
  • Standard Cable Length: 500mm (±10mm)
  • Installation Type: External Adhesive or Non-Metallic Bracket Mount
  • Waterproof Rating: IP67

Usage Notes

  • Normal detection is specified for liquids with dynamic viscosity below 10mPa·s; 10-30mPa·s may affect detection, while liquids above 30mPa·s are unsuitable because liquid may adhere to the container wall.
  • For outdoor installation, protect the main body from direct sunlight, direct rain runoff and excessive heat.
  • Use a suitable input interface when connecting the OUT line to a controller; the input must tolerate the sensor's output voltage.

Package Includes

  • 1 × XKC-Y25-V DC 5-24V Non-Contact Liquid Level Sensor with Cable